Solutions · Modbus

The industrial standard for metering.

Modbus is the workhorse protocol of industrial energy meters, controllers and substations. Over an RS-485 link, Metbox PRO reads your Modbus devices and sends the data to the platform over 4G - SCADA-style integration, without the SCADA.

Modbus RTU / TCP · RS-485 Gateway-to-platform over 4G
Modbus device on an RS-485 line to a Metbox gateway, data sent to the platform over 4G
Compatible devices

Works with 60+ Modbus devices from 12 manufacturers

Browse the full list
What it is

The industrial protocol for energy data

Modbus is a mature, openly published serial protocol used across industrial and building equipment. A gateway acts as the client and polls each device by address, reading values from its registers - the standard behind energy meters, heating substations and controllers.

It runs as Modbus RTU over RS-485 serial wiring, or Modbus TCP over Ethernet. Metbox PRO speaks Modbus alongside wired M-Bus, so mixed installations come online through one gateway.

The essentials

What makes Modbus a good fit

An open, ubiquitous standard for industrial equipment - simple, robust, and supported by virtually every energy meter and controller vendor.

Built for industry

The de-facto standard for industrial energy meters, controllers and substations - proven on the plant floor for decades.

Open & ubiquitous

An openly published protocol implemented by virtually every meter and controller vendor - no licensing, broad support.

RS-485 multi-drop

Many devices share one RS-485 line, each with its own address, so a single run reaches a whole room of equipment.

Register-based reads

Values live in well-defined holding and input registers, giving precise access to exactly the data you need.

Modbus & M-Bus together

Metbox PRO reads Modbus alongside wired M-Bus, so mixed buildings and plants come online through one gateway.

Sent on over 4G

The gateway collects the bus and forwards readings to the Metbox platform over the 4G mobile network.

At a glance

The protocol, in short

The key facts that matter when you're planning a deployment.

Modbus - quick spec
Protocol
Modbus RTU / TCP
Medium
RS-485 serial · Ethernet
Topology
Multi-drop · client polls servers
Addressing
Unit IDs 1–247 · registers
Power
Mains / loop-powered devices
Best for
Industrial energy meters & substations
Variants

The variants you'll come across

Modbus comes in a few flavours for different media. Metbox PRO handles the common serial ones.

RTU

Modbus RTU

Compact binary framing over RS-485 serial - the most common variant for energy meters and controllers.

ASCII

Modbus ASCII

A human-readable serial framing used by some legacy devices, carried on the same RS-485 wiring.

TCP

Modbus TCP

Modbus carried over Ethernet/IP - used where equipment is already on a network.

How it works with Metbox

From bus to platform in four steps

Wire the devices, connect the gateway, and readings flow up over 4G - no SCADA system required.

01

Devices on RS-485

Industrial energy meters, substations and controllers share one Modbus RS-485 line, each with its own address.

02

Metbox PRO polls

The gateway acts as the Modbus client, polling each device and reading the registers you need.

03

Platform ingests

Readings travel over 4G to the Metbox platform, arriving validated and structured.

04

Export & integrate

Export consumption as CSV/XLSX or connect by API to billing, ERP and energy-management platforms.

Bring your Modbus devices online

Tell the Metbox team which Modbus meters and controllers you run. We'll confirm compatibility and set up Metbox PRO for your site.